Feature:
1. This relay output optocoupler isolation to enhance anti?interference ability.
2. Industrial grade circuit board, set parameters will always be remembered after power off.
3. The signal terminal voltage signal can be maintained for a long time, and the power supply anti?reverse function is added.
4. With good performance, the output capacity can control equipment within DC 30V5A or AC 220V5A.
5. Strict quality control and quality assurance, high safety factor, can be used with peace of mind.
Specification:
Item Type: Relay Timer Module Material: ABS
Purpose: Street lamp, solenoid valve, instrumentation, LED display control
Working Voltage: DC12V
Quiescent Current: 20mA
Working Current: 50mA
Signal Source: Positive trigger, PNP, active high
Output Ability: Can control equipment within DC 30V5A or AC 220V5A
Service Life: more than 100,000 times
Working Temperature: 30~85 celsius
Function List:
P1: The signal triggers the relay to close, the time is up, the relay is disconnected, during the timing period
A: Trigger again is invalid C: Trigger again to retiming E: Trigger the relay again to reset the timer
P2: Signal trigger start timing time T1, when the time is up, the relay pullin time T2 is disconnected (reset)
A: Trigger again is invalid C: Trigger again to retiming E: Start timing without triggering power
P3: Recycling use: turn on T1, turn off T2, endless loop. T1 and T2, the time is adjustable
If a certain parameter is 0 when on or off, it can realize the poweron timing is turned on or the poweron timing is not cycled.
A: The relay is turned on immediately after poweron C: The relay is turned off and then turned on after poweron
P4: When there is a signal, the relay is closed and kept closed, the signal disappears, and the timing starts. When the time is up, the relay is disconnected. During the timing, give the signal again, the timing is cancelled, the relay is maintained, the signal disappears, and the timing is restarted.
P5: Output when the trigger reaches the time X once, and the output is prohibited when the trigger reaches the time Y again. It is suitable for products that require a certain stabilization time to operate (the first time you do not press K to disconnect and then pull in).
P6: Trigger once and output one time. When the number of triggers is enough, the signal will be output. It is suitable for products that require a certain number of triggers to operate. The final output time is the first time of the first mode (the first time you don"t press K is the off Open state, pull in after trigger).
Button Setting Instructions:
K1: Function selection key: long press K1 key for 2 seconds, P* appears, short press K1 to select mode, press K2 to enter mode
K2: Shift key: press to adjust the position of the digital tube flashing, which digital tube flashes, K3 will adjust the value of the flashing digital tube. Until K2 is pressed, the digital tube no longer flashes, the setting time is completed, the setting time is automatically saved and the memory is power off
K3: When the nixie tube flashes: K3 adjusts the number to change, 0 to 9 change in sequence.
When the digital tube display is normal: K3 adjusts the position of the decimal point, the decimal point in the ones place means 0 to 999 minutes; the tens place means 0 to 99.9 seconds; no decimal point means 0 to 999snt means 0 to 999s.
Package List:
1 x Relay Timer Module
Note:
1: After the working mode is selected, short press K3 to enter the function A, C, E switch, the digital tube will briefly display A or C or E, the default is A, press K2 to confirm the setting.2: Function P‑2 and P‑3 have 2 groups of time to be adjusted. Press K2 six times as a cycle, adjust one time for the first three times, and adjust another time for the last three times. (The blue light is on to set the time for the relay to close, and the blue light off means to set the time for the relay to turn off.)This relay output optocoupler isolation to enhance anti?interference ability.
Industrial grade circuit board, set parameters will always be remembered after power off.
The signal terminal voltage signal can be maintained for a long time, and the power supply anti?reverse function is added.
With good performance, the output capacity can control equipment within DC 30V5A or AC 220V5A.
Strict quality control and quality assurance, high safety factor, can be used with peace of mind.