Feature:
1. Warning Device: Integrated access control controller, power failure alarm and digital input alarm device, support remote control, power off or power on alarm, single channel alarm input (door magnets, opposing beam, etc.)
2. Control and Alarm Method: Support phone calls, send SMS commands to devices for remote control, send SMS to designated recipients for device alarms, with a total of 200 control and alarm users
3. DIN Alarm Unit: Supports one channel DIN input alarm. When the sensor is triggered, the controller will issue an alarm to the set user through call and SMS. You can also set up or disable the alarm
4. Power Off and On Alarm: When the external power supply is powered on or off, the remote controller will issue an alarm in real time through phone call or SMS, with a relay status power off memory function
5. Programmable Function: Programmable alarm SMS text, power failure, relay switch, DIN alarm SMS text, device name. You can program the text according to your needs, and meeting the requirements of more scenarios
Specification:
Item Type: Door Access Controller
Model: DN371
Material: ABS
Rated Voltage: DC 9V36V 1A or 2A
Working Temperature: 10 celsius 60 celsius
Storage Temperature: 20 celsius 60 celsius
Relative Humidity: 1090percent , non condensing
Output Relay Related Voltage: 3A 240V AC
Antenna: 50 Ohm SMA
Battery: Lithium Ion Battery 380mAh (Built in)
Remote Control Method: Freely phone call, SMS command to the device
Device Alarm Method: Freely phone call, SMS to designated recipient
Alarm Record: 1000 records
Control and Alarm User Number: 200 Users
Voltage Input: 936V DC 1A 2A 3A 4A 5A, etc
Port: 1 Channel Relay Output, 1 Channel DIN Input.
Package List:
1 x Controller
1 x Terminal
1 x User ManualWarning Device: Integrated access control controller, power failure alarm and digital input alarm device, support remote control, power off or power on alarm, single channel alarm input (door magnets, opposing beam, etc.)
Control and Alarm Method: Support phone calls, send SMS commands to devices for remote control, send SMS to designated recipients for device alarms, with a total of 200 control and alarm users
DIN Alarm Unit: Supports one channel DIN input alarm. When the sensor is triggered, the controller will issue an alarm to the set user through call and SMS. You can also set up or disable the alarm
Power Off and On Alarm: When the external power supply is powered on or off, the remote controller will issue an alarm in real time through phone call or SMS, with a relay status power off memory function
Programmable Function: Programmable alarm SMS text, power failure, relay switch, DIN alarm SMS text, device name. You can program the text according to your needs, and meeting the requirements of more scenarios